Audit identifies cause of Telstra's nationwide outage
* Telstra's July 8 outage began at 2:50am following a planned NTP (Network Time Protocol) timing chassis change, according to an independent investigation into what triggered the network failure
* When the chassis came back online, its internal GPS card had reset and began sending an incorrect date - 2006 - into the network
* To prevent the issue, the GPS card required a firmware update, stipulated in bulletins sent by the supplier
* While the chassis change triggered the outage, steps leading up to it go as far back as 2020
* At its peak, the outage impacted 45 per cent of all Telstra calls and data sessions,
* Some users were unable to make or receive voice calls including Emergency Calls, send or receive messages, or access mobile data
* Telstra undertook more than 630 welfare checks on customers prevented from having triple-zero calls connected
* Alarms in Telstra's system were not recognised as signifying potential broader network issues.
*Telstra failed to recognise and prioritise network time protocols (NTP)
* The department responsible for the failure point had not sufficiently modernised and maintained adequate support for NTP in part due to budgetary constraints
* A lack of competency, curiosity and technical expertise meant problems arose, but no one investigated them
* Two engineers who were involved in the planned change were on mandatory standdown when the outage was noticed
* Despite the change associated with the outage being seen as high risk, no pre-checks of equipment and software were undertaken
*After the change, no testing was done to check key functions were working correctly
5News aggregated this summary from the outlet’s public feed. The full article, with all the context, is on www.perthnow.com.au — the content belongs to PerthNow.